Salient Features of S400D model on line UPS systems.
1.True On-line
double conversion Technology, Dual Microprocessor and
Digital Signal Processing ( DSP) based System. IGBT Rectifier and
IGBT Inverter. Power factor correction, input PF >0.99 with any
load. Rugged and Robust design to provide fit
and forget reliability. The Best Available technology for guarding
mission critical systems.
2. Wide
input voltage range (+25%, -30%). 290V to 518V Phase to phase
Voltage. This UPS is designed to work under
wide input voltage range , increases reliability and saves battery
cost.
3.Reverse
Phase sequence operation:
UPS corrects phase sequence automatically , increasing reliability.
4. This UPS supplies
Precise Sine Wave power thus providing protection from all
type of disturbances including Lightning and surges, Voltage sags,
Harmonics and power Outages. With capability to cater 100% non
Linear load. Option for Isolated out put with constant
frequency. suitable for any kind of
load.
5. 1+1 Redundant configuration possible
with one more UPS for 100% availability. 2 UPSs can be configured to
work on common battery bank. DG can also be connected to this UPS as
an additional back up source in this configuration.
6. DG Compatibility.Due to unity input power factor, wide input
frequency and voltage range. DG with 1.5 Times capacity is
sufficient for this ups.
7.Battery management features including Temperature compensated
charging of batteries to protect the batteries.
8. Fault Tolerance. The fail-safe
static bypass ensure the power supply to your critical load even
during UPS over load or fault conditions. In case of a fault the
load is transferred to the stand by (by pass) Power.
9. The servicing of the UPS can be
done, components can be repaired/replaced and restart the systems
and transfer the load to UPS, all are possible
without disturbing the load.
10.Facility for online battery test
even when the critical load is on.
11. LCD Display l on the front panel.
The user can read the status of the UPS with readings of all
parameters including voltages current of input/output, Battery,
load, back up time, battery charge etc. from the LCD panel.
12. Data logging and event history.
Supper 400 can identify and display 45 fault conditions on its front
panel. Also It can store and display 200 alarm events (input over
voltage, power failure, power restoration, ups on,off etc.). the
customer can find out if there was a power failure last week on one
particular day and what time it happened and what was the load at
that time and What was the out put voltage.
13.Option for Intelligent network
interface port. UPS monitoring is possible with site Net
software. All major OS platforms are supported including windows,
UNIX, Novel, HP, DEC and many others.
14. Cold start facility with 100% load
in the absence of utility power.
15. Smallest foot print This Equipment
is constructed zinc-plated steel structure an the front panel is
held in place by a snap fit arrangement. Size (WxDxH) 450x650x1150
(mm).
16 . Excellent service backup as we are
specialist in UPS System having 25 years of
experience in UPS maintenance We give our maintenance
support to More than 1000 major organizations. through Liebert
(Emerson) trained engineers. These are in addition to the support
from Emerson , who is having country wide service network with
India's best manpower.
All these are in addition to the normal specifications of a
standard UPS system
For further details, please call us 0712 2438907,
2428319
E-mail ;simielectronics1988@gmail.com;simisweta@satyam.net.in
visit www.emersonnetworkpower.co.in
Prices
10 KVA Rs.200000.00
20 KVA Rs.275000.00
Plus Taxes
|