*
Support FAQ    
Support Liebert Faq UPS Systems Medical Systems

 Highly Reliable UPS

     
     
Liebert UPS systems from 600VA TO 4800KVA
Surge Suppressors
Liebert Precision Air Conditioning Systems
Batteries, Inverters, Stabilizers SMF, Tubular, Inverter and 2 volt VRLA long life batteries
Introduction to Simi
   
ref

   7400M

Hipulse

Nxa 10K- 120KVA

itrust 30K-60K

 

Liebert  Higher Capacity UPS systems For The Digital World And Industrial Automation in the Capacity  of 20-800KVA , in single module and which can be UPGRADED  to 4800KVA capacity.

Hipulse, 7400M,   Nxa, Itrustmodels

Liebert Series 7400M ( 30/40/60 KVA)

Maximum Protection for Mission Critical Applications

The Series 7400M is a Compact 3 phase UPS system with Optimum load performance and Battery Management System. The Series 7400M is ideally suitable for critical systems such as Digital Drives & Automation, Distributed Digital Process Control System, Programmable Logic Controllers, Critical Motor Loads, Medical Diagnostics, Computers and Telecommunications.

Clean, continuous power is essential for critical equipment and telecommunications. But high Standards of power cannot be guaranteedfrom mains. The Series 7400M UPS offer IGBT technology along with PWM(Pulse Width Modification) ensuring the electrical supply to be reliable and free of unwanted disturbances.
With three models offering power ranges from 30-40 and 60 KVA

Some other salient Features of the Series 7400M
• 30, 40 and 60 kVA models
• High efficiency performance
• High reliability to maximize system availability
• Handles 3:1 crest factor loads without de-rating
• Fully compatible with non-linear and unbalanced loads
• Microprocessor controlled temperature compensated battery charging system maximizes battery life
• Programmable battery testing
• LCD display for continuous monitoring.
• Real-time battery status
• Integral maintenance bypass.
• Low acoustic noise levels (< 60 db).
• Compatible with IBM AS/400 Computer systems 

Hipulse UPS Digital UPS ,

30KVA to 150KVA with 1 phase out put  & 80KVA to 800KVA with 3 phase out put               

 From Reliability to availability. scalability to redundancy. user-friendliness to maintainability .
 paralleliibility to connectivity, investment to protection to lower cost of ownership,
Hipulse addresses them all efficiently and effectively. Hipulse is carefully designed to maximize the availability of your critical loads to ensure that your business is protected to the maximum extent possible against  power quality problems as well as complete power failure
 
  • Liebert Hipulse model UPS  available in two categories such as :-
30KVA to 150 KVA with 3 phase input and 1 phase out put  and
80KVA to 800 KVA with 3 phase input and 3 phase out put.
        
  Application:-
  1. Facility-wide networks(30-150KVA/80-800KVA
  2. Medical equipment
  3. Industrial process-Automation
  4. Transport Automation
  5. Large Computer Rooms
 
 
Features:-
  1. On-line Double Conversion
  2. IGBT-based PWM Inverter
  3. Wideinput voltage tolerence(+10/-15%)
  4. Wide input feaquency tolerence(5%)
  5. Automatic battery testing
  6. Common battery sharing kit(optional)with1+1 configuration
  7. Built-in maintenance bypass (single and 1+NModels)
  8. Modular design of inverter brige for higher rated UPS modules like600&800kVA
  9.  UPS modules in Dual Bus configuration using optional HiSync on the Upstream               (with UPS),HiSwitch in the downstream (after UPS)and load-end Smart Switches
  10. Provision to use any type of battery:Wet cells(Tubular or Plant),valve Regulated Lead Acid(VRLA)/Maintenance free and Nickel Cadmium
  11. Field settability of end-cell voltage of the battery
  12. Intelligence web communications and automatic graceful computer shutdown operations
  13. N form software for full-scale and cost-effective monitoring
  14. Site scan web solution tool for online monitoring
Liebert Nxa model UPS  10 KVA to 120 KVA

Features:
Stratified cooling techniques
Versatile and simultaneous communication Facilities
Compact Active and passive footprints
Capability to handle 0.9 leading power factor loads
Capability to handle 100% unbalanced loading
Back feed Protection
User flexibility in selecting effective configuration for the application
Large and user-friendly LCD display in twelve different languages
Compatibility to VRLA (SMF), LATB, Nickel Cadmium Batteries
Black Start Facility
 

Benefits:
Hi – Availability of Quality Power
Reduced Cost of Ownership
Upstream Green Power
Ease & Simplicity in Scalability & Redundancy
Investment Protection

 
You may please contact if you:
1.Need a Highly Reliable UPS system.   
2.Need any type of Batteries.
3.Having problem with any existing UPS systems.
4.Need consultancy in solving any power related problems.
 
Contact Mr.Mathew George Thoduka
Ph. 91-712, 2428319, 2438907, Fax: 0712 6612030
e mail:
simielectronics1988@gmail.com; simisweta@satyam.net.in
so call today!!!!!!!!!!!!!!
 
 
 
 

Why Liebert              About us             Our customers            Contact us             Site Map  

Copyright ©  Simi Electronics, Nagpur. All Rights Reserved.